Check with seller How to Determine the Temperature Measurement Point of Box-type Experimental Electric Furnace

Published date: April 30, 2020
Views: 8


According to the size of the working area of the box furnace, the size of the temperature measurement frame is designed to determine 5 temperature measurement points and 1 monitoring point. Place the 5 temperature measurement points at the center of the work area and at the four corners of the front lower left, front upper right, rear upper left, rear lower right (as shown in Figures 1, 2, 3, 4, and 5 above). The monitoring point is located in the working area where the extension direction of the temperature control thermocouple end does not exceed 150mm. If the center point does not exceed 150mm from the temperature control thermocouple measurement point, the center point is regarded as the monitoring point.

read more:

1400 degree double temperature zone vacuum tube atmosphere furnace
Vacuum brazing furnace for diamond
Chinas Best CNC Milling Machine

Share


Useful information

  • Avoid scams by acting locally or paying with PayPal
  • Never pay with Western Union, Moneygram or other anonymous payment services
  • Don't buy or sell outside of your country. Don't accept cashier cheques from outside your country
  • This site is never involved in any transaction, and does not handle payments, shipping, guarantee transactions, provide escrow services, or offer "buyer protection" or "seller certification"

Related listings

  • Measures to reduce electrode loss of electric furnace
    Home - Furniture - Garden Supplies - - April 21, 2020 Check with seller

    The main causes of electrode loss in steelmaking are chemical loss caused by oxidation and physical loss caused by electrode breakage. The reason of chemical loss is that the design of length and angle of oxygen lance on the inner wall of electric fu...

  • How to choose thermocouple for experimental furnace
    Home - Furniture - Garden Supplies - - April 17, 2020 Check with seller

    The thermocouple of the temperature measuring element of the experimental electric furnace is selected according to the use temperature. Today, I'd like to introduce the graduation number of the thermocouple and what temperature stage each graduation...

  • Vacuum method of experimental electric furnace
    Home - Furniture - Garden Supplies - - April 16, 2020 Check with seller

    Because the heating, cooling and other operations of metal workpieces need dozens or even dozens of actions to complete. These actions are carried out in the vacuum heat treatment furnace, which is inaccessible to the operators. Therefore, the automa...